120/120 Plus Digital Weight Indicator

As of: Wednesday, June 18, 2025
Save or Print to PDF
RL-120-plus-weigh-indicator

Standard Features

120

  • LED display
  • Configurable analog to digital measurement rate
  • Primary/secondary units configuration: lb, kg, ounces, grams
  • Five-button operation
  • Two independent communication ports
  • Programmable ticket format, up to two 180-character printout
  • Full front-panel digital calibration and configuration
  • Tilt stand
  • Three-stage digital filtering
  • Consecutive transaction numbering
  • Time and date (volatile)

120 Plus

  • LCD display
  • Internal rechargeable lithium battery and wall adapter
  • Power save feature for 700 hours of battery life
  • Ten stored tare values
  • Display hold (based on three second average)
  • Time and date
  • Configurable with Revolution® software

Approvals

NTEP Logo
LOGO Measurementcanada Approved BW
CE Mark

WARNING: Cancer and Reproductive Harm California Proposition 65

Digital Weight Indicator

With the 120/120 Plus digital weight indicator, there is no need to sacrifice quality for price. These digital weight indicators are designed to be a reliable, cost-effective solution for material handling or shipping and receiving applications. The 120/120 Plus drives up to four 350Ω load cells while three-stage digital filtering provides stable, accurate weight data. The 120/120 Plus's tactile front panel and easy-to-read display help to make scale operations effortless. Two independent communication ports provide full EDP and print ticket programmability.

120/120 Plus Specifications

Power:
120/120 Plus
Line voltages: 115 or 230 VAC
Frequency: 50 or 60 Hz

Battery Life:
120 Plus
60 hours with 1 x 350 ohm, 40 hours with 4 × 350 ohm load cells
Eight hour charge time

Excitation Voltage:
5 VDC, 4 × 350 ohm or 8 × 700 ohm load cells

Analog Signal Input Range:
-0.6 mV/V to 3.0 mV/V

Analog Signal Sensitivity:
0.3 μV/graduation minimum,
1.5 μV/grad recommended

A/D Sample Rate:
120: 3 to 30 Hz, software selectable
120 Plus: 30 Hz

Resolution:
Internal: 1,000,000 counts
Display: 10,000

System Linearity:
Within 0.01% of full scale

(Optional) Digital I/O:
120 Plus: 
Requires option card
24 volt source
Three digital inputs
Two digital outputs

Circuit Protection:
RFI, EMI, ESD protected

Load Cell Connection:
Cord grip entry
Detachable plug (optional)

Communication Port:
EDP port: Full duplex RS-232
Printer port: Output-only RS-232 or active 20 mA current loop
Both ports: 9600, 4800, 2400, 1200, 600, 300bps;
Seven or eight data bits; even, odd or no parity

Annunciators:
120/120 Plus: Center of zero, standstill, gross, net, lb, kg, oz, g
120 Plus: Battery, setpoint 1 and 2, Hold

Display:
120: 0.8 in (20 mm), six-digit red light emitting diode
(LED) display, seven-segment digits
120 Plus: 0.8 in (20 mm) six-digit LCD with backlight, seven-segment digits

Keys/Buttons:
120: 
Five-key flat membrane panel, tactile feel
120 Plus: 
Zero, tare, preset tare, hold, gross/net, units, numeric 0-9, clear, enter/print

Temperature:
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Operating: 14 °F to 122 °F (-10 °C to 50 °C)

Rating/Material:
Enclosure: Heavy gauge ABS

Weight:
2.6 lb (1.2 kg)

Warranty:
One-year limited

Approvals:
NTEP CC 03-059, Class III/IIIL 10,000d
Measurement Canada AM-5517
EU Test Certificate TC7626
CE Marked

120/120 Plus Dimensions

 

Dimensions
A 7.32 in (186 mm) C 3.74 in (95 mm) E 4.76 in (121 mm)
B 6.06 in (154 mm) D 1.65 in (42 mm)    

 

Parts

Part # Description
131923 Indicator,Desk 120 115/230VAC, Plastic Enclosure w/ Cord Grip for Load Cell, 5 Button Keypad, LED Display and Tilt Stand, NTEP, OIML/CE marked
103632 Indicator,Desk 120 PLUS 115VAC/230VAC, Plastic Enclosure, Full Keypad, LCD Display and Tilt Stand, NTEP, OIML/CE marked
107619 Indicator,Desk 120 PLUS with Digital I/O, 115VAC/230VAC, Plastic Enclosure, Full Keypad, LCD Display and Tilt Stand

Options

Part # Description
Options/Accessories
93205 Connector, for 120 indicator,w/6m length Load Cell Cable (requires 103507)
82505 Connector,6-Pin Socket External load cell connector(requires 103507)
103507 Ind Opt,Load Cell Plug External Disconnect for 120 Indicator(requires 82505 or 93205)
107620 Ind OPT,Digital I/O Card for 120 Plus.
105670 Connector, 15-pin HDB-SUB 120 plus (Connector with gray housing)
106705 Cable, I/O Interface for 120 Plus, 15-pin D-SUB HD Connector with Blunt End, 2 meter cable length
76699 LIT,120 Rice Lake 120 Installation Manual
105914 LIT,Manual 120 Plus 120 Plus Installation Manual
120 Primary Component Parts
131924 Board ASSY,CPU Desk 120 With Volts Cal. For Use With Cord Grip Style. 10V/Meter Immunity
78610 Overlay, Membrane Switch Panel Desk 120 Indicator
131925 Power Supply, 9V Wall 115/230VAC 9VDC 550mA Wall Mount Unregulated Adapter.
64794 Cable,Null Modem DB9F/M DB9F To DB9M, 6 feet
120 Plus Primary Component Parts
103634 Board Assy,CPU 120 Plus LCD Display with Backlight
103635 Overlay,Membrane Switch 120 Plus Indicator
103636 Power Supply,120 Plus Wall Adapter, 115/230VAC, 5VDC
103637 Battery,120 Plus, 3.7 VDC 4000 mAh Lithium Rechargable Battery, Ion

Rice Lake 800-472-6703