Power Consumption: 6 W/8 W (Versions /01, /04, /06, /07)
Supply Voltage: 24 VDC, ±20%
Analogue Output: 0 to 10 or 4 or 20 mA, internal resolution 16-bit, usable step-width: 0.5 μA max. load 500 O; user configurable
Serial Interfaces: RS-422/485 via screw terminals Protocol: Remote display, SMA and Minebea digital scales (XBPI–protocol)
Electrical Connections: All electrical connections via modular screw terminals for 2.5 mm 2 max. System Phoenix/COMBICO
Input Range: 7.5 mV (appr. 4.8 Mio. div.) Usable resolution: 0.2 μV/d
Input Signal: Measuring signal: 0 to 36 mV (for 100 % nominal load)
Control Outputs: Quantity: 3 opto-isolated output, passive Voltage: max. 30 VDC Current: max. 30 mA Functions: Limits, weight status
|
Control Inputs: Quantity: 3, opto-isolated input, passive Functions: zero setting, taring Voltage: max. 30 VDC Current: max. 10 mA
Ethernet Interface (functions): Ethernet IP and Modbus/TCP Definition of an IP address: – AutoIP; – DHCP Server classification; – manual entering of an IP address Automatic detection of signal transmission and corresponding change over (cross-over or patch cable) Webservice via SOAP|UPnP (Simple Object Access Protocol) Synchronal Modbus UDP
In/Output: All I/O circuits fully galvanically isolated from sensor input and supply
Load Cell Connection: All strain gauge load cells; four- or six-wire connection
Load Cell Supply: 12 V, short-circuit proof. External load cell supply possible
Digital Filter for Load Cell: 4th order (low pass), Bessel, aperiodic or Butterworth
Minimum Load Impedance: Min. 75 ohm e.g. 6 load cells with 600 ohm or 4 load cells with 350 ohm
Measuring Principle: Measuring amplifier: Delta-Sigma converter Measuring time: min 5 ms - max. 1600 ms
|
Linearity: < 0.002 %
Status Indicator: Status LEDs to signal operation and error conditions.
Temperature Effects: Zero: TK0 m < 0.02 μV/K RTI Span: TKspan < ± 2 ppm/K
Dimensions: (L × W × H) Version 00: 3.9 × 4.6 × 1.77 in (99 × 116 × 45 mm) Versions 01, 04, 06, 07: 3.9 × 4.6 × 2.68 in (99 × 116 × 68 mm)
Housing: Housing IP20 according to DIN 40050 Mounting on DIN Rail 35 mm according to DIN 46277 Material: polyamide RoHS conform
Temperature: WandM: 14 °F to 104 °F (–10 °C to 40 °C) Operation: 14 °F to 122 °F (–10 °C to 50 °C) Storage: -40 °F to 158 °F (–40 °C to 70 °C)
Weight: Version 00: Net: 0.29 kg Versions 01, 04, 06, 07 Net: 0.35 kg
Approvals: OIML R76min. verification interval: 0.5 μV/e 10,000 e class III acc. to EN 45501
|