Rice Lake RL1260 Aluminum, Single-Point Load Cell

As of: Wednesday, July 9, 2025
Save or Print to PDF
1 US Singlepoint RL1260 Aluminum

Standard Features

High-capacity, off-center loading aluminum load cell. This model is of the two-beam design, and is specially coated to assure durability in harsh environments. 75 kg and 300 kg capacities available. Complete with 10 ft of load cell cable.

Approvals

NTEP Logo
LOGO FM CUS

WARNING: Cancer and Reproductive Harm California Proposition 65

RL1260 Load Cell Specifications

Full Scale Output:
2.0 mV/V

Output Resistance:
350 (±3) ohm

Input Resistance:
415 (±15) ohm

Material/Finish:
Anodized aluminum

Temperature:
Compensated:
14 °F to 104 °F (-10 °C to 40 °C)
Operating:
0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Environmentally sealed, IP67

Safe Overload:
150% of full scale at center loading point

Rated Excitation:
5 to 10 VDC (15 V maximum)

Combined Error:
0.02% full scale

Insulation Resistance:
5,000 megohm

Cable Length:
10 ft

Cable Diameter:
0.220 in
Polyurethane jacket

Cable Color Code:
Green +Excitation
Black –Excitation
Red +Signal
White –Signal
Blue +Sense
Brown –Sense

Max Platform Size:
24 × 24 in

Warranty:
Two-year limited

Approvals:
cFMus
NTEP 97-139

RL1260 Load Cell Dimensions

Rated Capacity A B C C1 D E F G H
kg/mm
75 and 300 188.0 52.0 35.0 142.0 5.5 63.5 50.0 5/16-18 UNC 62.3

 

 

Parts

Part # Description

Rice Lake 800-472-6703

An ISO 9001 Registered Company ©2024 Rice Lake Weighing Systems