Standard Features

This stainless steel, welded-seal, single-ended beam provides excellent protection against corrosive and washdown environments. This model is also a direct replacement cell for the Mettler Toledo® 745 Mount. It is ideally suited for low-profile platforms and vessel weighing.

Approvals

NTEP Logo
LOGO FM Approved

WARNING: Cancer and Reproductive Harm California Proposition 65

RL30745 Load Cell Specifications

Full Scale Output:
2.0 mV/V, ±0.002 mV/V

Bridge Resistance:
350 ohm, nominal

Material/Finish:
Stainless steel

Temperature:
Compensated range
14 °F to 104 °F (-10 °C to 40 °C)
Operating range
0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Welded-seal, IP67

Safe Overload:
150% full scale

Safe Sideload:
100% full scale

Rated Excitation:
5 to 10 VDC (15 V maximum)

Combined Error:
0.03% 

Non-repeatability:
0.01% full scale

Insulation Resistance:
5,000 megohm

Cable Length:
30 ft

Cable Diameter:
0.190 in polyurethane jacket

Deflection at Capacity:
500 to 2,500 lb: 0.010 in
5,000 to 10,000 lb: 0.012 in

Cable Color Code:
Green +Excitation
Black –Excitation
White +Signal
Red –Signal
Yellow Shield

Warranty:
Two-year limited

Approvals:
FM
NTEP 06-023

RL30745 Load Cell Dimensions

Rated Capacity A B C D E F G H I K L
lb/in
10,000 1.68 3.75 1.50 0.88 1.06 1.38 0.44 0.75 6.87 1.68 3.03

 

 