RLD 10K

Standard Features

The RLD-10K double-ended shear beam load cell has a low profile and rigid mount. The RLD-10K is ideal for
applications where suspension mounts are not suitable, profile increases don't work, or dynamic forces are present.

RLD-10K Specifications

Full Scale Output:
3.0 mV/V at 10,000 lb

Output Resistance:
700 ohm (nominal)

Input Resistance:
780 ohm (nominal)

Material/Finish:
Alloy steel

Temperature:
14 °F to 104 °F (-10 °C to 40 °C)

Rated Excitation:
5 to 15 VDC

Non-linearity:
±0.03% full scale

Insulation Resistance:
10 gigohms at 50 VDC

Seal Type:
Environmentally sealed, IP67

 

Connector Type:
Amphenol, 5-pin (male)

Connection Pin Out:
A - Excitation +
B - Signal +
C - Signal -
D - Excitation -
E - Shield

Warranty:
One-year limited

RLD-10K Dimensions

Parts

Part # Description
120959 Load Cell,DEB 3.0 mV/V 10,000lb/4536KG, 1.5 x 1.625 x 10.25, 5 Pin CONN OnBoard Weighing