UJB3T6 DC Transient Protection

Rice Lake Weighing Systems

As of: Tuesday, November 3, 2026

1 US JB 21134 (1)

Standard Features

  • Protects load cells from voltage transients

  • Compatible with signals down to 1 μV per grad

  • Factory serviceable

  • Full six-wire with shield protection

  • #6 SEMS screw type; accepts spade lugs, tinned leads or bare wires up to #12 AWG

  • Up to eight parallel or summed load cells

Applications
  • Installations exposed to significant transients

  • Environments where serial communication lines and load cells must be protected

The factory-serviceable UJB3T6 DC Transient Protector can protect up to six data lines or eight load cells. The fiberglass reinforced polyester enclosure can withstand up to 40 psi in washdown applications.

UJB3T6 DC Transient Protector Specifications

Protection Type:
Six-wire type with separate shield

Maximum Excitation Voltage:
20 VDC or 20 VAC

Clamping Voltage:
75 VDC or 75 VAC

Clamping Time:
75 VDC Stages < 100 nanoseconds typical

Peak Surge Currents:
75 VDC Stage, 5,000 A

Maximum Serial Transmission Rate:
50,000 baud

Series Resistance:
0.219 ohm typical

Series Inductance:
110 µH typical

Grounding:
20 ft insulated #10 AWG wire

Cable Fitting:
Two nylon strain reliefs for 0.079 to 0.236 in diameter cable

Enclosure:
NEMA Type 4X, 40 psi maximum washdown
Fiberglass reinforced polyester (FRP)

Temperature:
Operating:
4 to 104 °F (-10 to 40 °C)

Circuit Board:
6.75 × 4.75 in with anti-fungal coating

Dimensions:
(L × W × H)
7.63 × 6.63 × 3.25 in

Warranty:
One-year limited

UJB3T6 DC Transient Protector Dimensions

 

Part #DescriptionList Price
21134UJB-3T6 Load Cell ProtectionList Price: $550.00

Part #DescriptionList Price
21135List Price: $285.00

www.ricelake.com | 800-472-6703

An ISO 9001 Registered Company ©2026 Rice Lake Weighing Systems