VPG® Celtron® STC Alloy Steel, S-Beam Load Cell

As of: Friday, July 11, 2025
Save or Print to PDF
rl-VPG-Celtron-STC-S-Beam-load-cell

Standard Features

Nickel plated, alloy steel construction. Suited for batching, filling and hopper/tank weighing applications. Capacities range from 250 lb to 40,000 lb. Comes with 20 ft of load cell cable.

Approvals

NTEP Logo
LOGO FM CUS

WARNING: Cancer and Reproductive Harm California Proposition 65

STC Load Cell Specifications

Full Scale Output:
3.0 mV/V nominal

Output Resistance:
350 (± 3) ohm

Input Resistance:
385 (± 5) ohm

Material/Finish:
High-alloy steel, nickel plated

Temperature:
Compensated: 14 °F to 104 °F (-10 °C to 40 °C)
Operating: 0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Environmentally sealed, IP67

Safe Overload:
150% full scale

Combined Error:
0.02% full scale

Rated Excitation:
5 to 15 VDC

Non-repeatability:
0.01% full scale

Insulation Resistance:
5,000 megohm

Cable Length:
20 ft

Cable Diameter:
250 to 20,000 lb: 0.200 in
40,000 lb: 0.305 in
Polyurethane jacket

Cable Color Code:
Red +Excitation
Black –Excitation
Green +Signal
White –Signal

Warranty:
One-year limited

Approvals:
cFMus
NTEP

STC Load Cell Dimensions

Rated Capacity A B C D E
lb/in
250 3/8-24 UNF 0.75 0.50 2.00 3.00
500 to 1,500 1/2-20 UNF 1.00 0.75 2.00 3.00
2,000 to 3,000 1/2-20 UNF 1.25 1.00 2.00 3.00
5,000 3/4-16 UNF 1.25 1.00 3.00 4.25
10,000 3/4-16 UNF 1.25 1.00 3.50 4.75
15,000 1-14 UNS 1.50 1.25 4.00 5.50
20,000 1 1/4-12 UNF 2.19 2.00 5.00 7.00
40,000 1 1/2-12 UNF 2.75 2.50 6.00 10.00

 

 

Parts

Part # Description
NTEP Certified
30047 Load Cell,SBM STC-250 250 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30051 Load Cell,SBM STC-500 500 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30054 Load Cell,SBM STC-750 750 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30067 Load Cell,SBM STC-1K 1,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30069 Load Cell,SBM STC-1.5K 1,500 lb 20ft 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30072 Load Cell,SBM STC-2K 2,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30073 Load Cell,SBM STC-2.5K 2,500 lb 20ft 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30074 Load Cell,SBM STC-3K 3,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30076 Load Cell,SBM STC-5K 5,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30077 Load Cell,SBM STC-10K 10,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30078 Load Cell,SBM STC-15K 15,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
30079 Load Cell,SBM STC-20K 20,000 lb 20ft Celtron 3mV/V 350 OHM WW NTEP IIIL 10 S IP67 FM
Non-NTEP Certified
46674 Load Cell,SBM STC-40K 40000lb 20ft Celtron 3mV/V 350 Ohm WW IP67
30ft Cable Matched Outputs
67881 Load Cell,SBM STC-5k 5,000lb 30ft Celtron 3mV/V -/+.2% 350 OHM WW NTEP III 5 S IIIL 10S w/ 6in. Leads
67882 Load Cell,SBM STC-3k 3,000lb 30ft Celtron 3mV/V -/+.2% 350 OHM WW NTEP III 5 S IIIL 10S w/ 6in. Leads
67883 Load Cell,SBM STC-20k 20,000lb 30ft Celtron 3mV/V -/+.2% 350 OHM WW NTEP III 5 S IIIL 10S w/ 6in. Leads

Rice Lake 800-472-6703