VPG Tedea-Huntleigh 1010/1015 Aluminum, Single-Point Load Cell

As of: Friday, July 11, 2025
Save or Print to PDF
rl-VPG-Tedea-Huntleigh-1010-1015-load-cell

Standard Features

Off-center loading load cell designed for direct mounting of a weighing platform and simplified construction of platform scales. Long-term stability and durability are maintained. Load cells with potted cavities are available for improved performance in damp environments. The model 1015 has a balanced bridge for applications where multiple cells are used. Capacities range from 3 kg to 90 kg.

Approvals

NTEP Logo
LOGO FM CUS

WARNING: Cancer and Reproductive Harm California Proposition 65

1010/1015 Load Cell Specifications

Full Scale Output:
2.0 mV/V 

Output Resistance:
350 (±3) ohm

Input Resistance:
Model 1010: 415 (±15) ohm
Model 1015: 350 (±3) ohm 

Material/Finish:
Aluminum

Temperature:
Compensated:
14 °F to 104 °F (-10 °C to 40 °C)
Operating:
0 °F to 150 °F (-18 °C to 65 °C)

Seal Type:
Environmentally sealed
Potted: IP67
Unpotted: IP65

Safe Overload:
150% at center of loading point, full scale

Rated Excitation:
5 to 10 VDC (15 V maximum)

Combined Error:
0.02% full scale

Deflection at Capacity:
0.015 in

Cable Length:
10 ft

Cable Diameter:
0.200 in
PVC jacket

Cable Color Code:
Green +Excitation
Black –Excitation
Red +Signal
White –Signal
Blue +Sense
Brown –Sense

Max Platform Size:
15.75 × 15.75 in

Warranty:
One-year limited

Approvals:
cFMus
NTEP

1010/1015 Load Cell Dimensions

Rated Capacity A B C D E F G H K L M N
kg/mm
3 to 90 118.0 34.0 3.0 110.5 66.0 80.0 25.0 (1010)
1/4-20 UNC x 13 DP
(1015)
M6 Metric
7.5 19.1 25.4 33.5

 

Parts

Part # Description
1010 NTEP Certified, Potted
33727 Load Cell,SPT 1010-10KG 10kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Potted IP67
33728 Load Cell,SPT 1010-15kg 15kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Potted IP67
33729 Load Cell,SPT 1010-20KG 20kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Potted IP67
33730 Load Cell,SPT 1010-30kg 30kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Potted IP67
33731 Load Cell,SPT 1010-50kg 50kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Potted IP67
1010 Non-NTEP, Potted
17462 Load Cell,SPT 1010-5kg 5kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
17463 Load Cell,SPT 1010-7kg 7kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
17464 Load Cell,SPT 1010-10kg 10kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
17482 Load Cell,SPT 1010-20kg 20kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
17475 Load Cell,SPT 1010-30kg 30kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
17476 Load Cell,SPT 1010-50kg 50kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
17471 Load Cell,SPT 1010-90kg 90kg 10ft 2mv/v 350 Ohm FM AL Class F Potted TH IP67
1010 NTEP Certified, Unpotted
33732 Load Cell,SPT 1010-5KG 5kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Unpotted
33733 Load Cell,SPT 1010-7KG 7kg 10ft TH 2mV/V 350 OHM NTEP III 5 S FM Al Unpotted
1010 Non-NTEP, Unpotted
17481 Load Cell,SPT 1010-3kg 3kg 10ft 2mv/v 350 Ohm FM AL Class F Unpotted TH
1015 NTEP Certified, Potted
188806 Load Cell, SPT 1015-7kg 7kg 3m TH 2mv/v 350 Ohm NTEP III 5 S FM AL Potted IP65 metric threads
188807 Load Cell, SPT 1015-10kg 10kg 3m TH 2mv/v 350 Ohm NTEP III 5 S FM AL Potted IP65 metric threads
188808 Load Cell, SPT 1015-15kg 15kg 3m TH 2mv/v 350 Ohm NTEP III 5 S FM AL Potted IP65 metric threads
188809 Load Cell, SPT 1015-20kg 20kg 3m TH 2mv/v 350 Ohm NTEP III 5 S FM AL Potted IP65 metric threads
188810 Load Cell, SPT 1015-30kg 30kg 3m TH 2mv/v 350 Ohm NTEP III 5 S FM AL Potted IP65 metric threads
188811 Load Cell, SPT 1015-50kg 50kg 3m TH 2mv/v 350 Ohm NTEP III 5 S FM AL Potted IP65 metric threads
1015 Non-NTEP, Potted
188804 Load Cell, SPT 1015-3kg 3kg 3m TH 2mv/v 350 Ohm FM AL Potted IP65 metric threads
188812 Load Cell, SPT 1015-90kg 90kg 3m TH 2mv/v 350 Ohm FM AL Potted IP65 metric threads

Rice Lake 800-472-6703

An ISO 9001 Registered Company ©2024 Rice Lake Weighing Systems