  • LCD display with white LED backlight
  • T4 temperature rating
  • Battery life display icon
  • Numeric keypad (882IS Plus)
  • Duplex fiber-optic interface
  • Power ON/OFF; battery save mode
  • Configurable local/remote mode
  • I/O module option: one serial port, optional analog output, optional fieldbus cards, Ethernet TCP/IP
  • Time & date (requires I/O module)
  • Setpoint functionality using secondary 920i indicator
  • FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file number 180948

Approvals

Some approval documents are available to view by clicking the icons below.

NTEP Logo LOGO Measurementcanada Approved BW OIML Logo OIML Logo CE Mark UKCA Black Fill LOGO FM CUS EX LOGO Iecex

WARNING: Cancer and Reproductive Harm California Proposition 65

Safe, Accurate Weight Readings in Hazardous Locations 

The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications. The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements.

Enhanced Connectivity

Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module. To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator.

Power:
Input: 5.8 to 7.9 VDC, 100 to 175 mA

Power Consumption:
0.25 W

Battery (optional):
60 hours with 4 × 350 ohm load cells
80 to 100 hours with 1 × 350 ohm load cell
8 to 10 hour charging time

Load Cell Excitation:
3.0 VDC at 87.5 ohm, 4.6 VDC at 700 ohm

Load Cell Current:
34 mA 4 × 350 ohm load cells or 8 × 700 ohm load cells

Load Cell Cabling:
Four- and six- wire with remote sensing (recommended)

Analog Signal Input Range:
-0.5mV/V to 4.0mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

 

 

 

Resolution:
Internal: 1,000,000 counts
Display: 10,000
The maximum number of allowed graduations will vary by application

Conversion Rate:
60 updates/second

Annunciators:
Center of Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off)

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 × 24 dot
matrix messaging area with white LED backlight

Keys/Buttons:
Flat membrane panel, tactile feel
882IS:
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, On/Off
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad, On/Off

 

Temperature:
14 °F to 104 °F (-10 °C to 40 °C)

Rating/Material:
IP66 enclosure
Stainless steel

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited

Intrinsic Safety:
FM/cFM
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 21 AEx/Ex ib IIIC T135°C Db
Ta = -10 °C to 40 °C (14 °F to 104 °F)
ATEX/IECEx
II 1 G Ex ia IIC T4 Ga
II 2 D Ex ib IIIC T135°C Db

Approvals:
NTEP CC 19-015
Measurement Canada AM-6124C
OIML R76/2006-A-NL1-21.11
EU Test Certificate T11166
CE Marked
UKCA
cULus Listed*
FM Entity
EX-ATEX
IECEx
*cULus is only applicable to 882IS I/O and battery charger

Dimensions
Without Battery
A 8.94 in (227 mm) E 9.96 in (253 mm)
B 7.66 in (195 mm) F 4.36 in (111 mm)
C 6.50 in (165 mm) G 8.37 in (213 mm)
D 8.10 in (206 mm)    
With Optional Battery and Tilt Stand
H 4.64 in (118 mm) K 10.29 in (261 mm)
I 5.00 in (127 mm) L 13.06 in (332 mm)
J 9.03 in (229 mm)    

 

 

 

 

Dimensions
Optional Power Supply
A 9.25 in (235 mm) C 3.11 in (79 mm)
B 6.20 in (158 mm)    

 

 

 

 

Dimensions
Optional I/O Module
A 10.00 in (254 mm) D 4.00 in (101.6 mm)
B 9.13 in (231.99 mm) E 2.75 in (69.9 mm)
C 6.91 in (175.5 mm) F 1.50 in (38.1 mm)

 

 

 

 

Resources / Downloads

Title View Email Category Type
Explosion-Proof vs. Intrinsically Safe Equipment Email Intrinsically Safe Articles
What Is Intrinsic Safety? Email Intrinsically Safe Articles

Title Download Email
882IS/882IS Plus Catalog Page Download Email
Explosive Environment Equipment Policy Download Email
Explosive Environment Solutions Download Email
Hazardous Atmospheres Download Email

Title Size Download Email Category
882IS DeviceNet Configuration Files 602 B Download Email Indicators / Controllers
882IS EtherNet/IP Configuration Files 1.6 KB Download Email Indicators / Controllers
882IS Profibus Configuration Files 1.2 KB Download Email Indicators / Controllers
882IS Profinet Configuration Files 2.8 KB Download Email Indicators / Controllers
IPConfig-Utility 54.1 KB Download Email Indicators / Controllers

Title Version Revision Download Email Category Archived
882IS/882IS Plus Intrinsically Safe Indicator Technical Manual 1 J Download Email Indicators / Controllers|Weight Indicators|Intrinsically Safe No
Single Analog Output Option Card for 882D and 882IS Addendum B Download Email Indicators / Controllers|Weight Indicators No
Interface Option Cards for 882D and 882IS Installation and Programming Manual D Download Email Indicator Hardware|Indicators / Controllers|Weight Indicators No
882IS IS6V2 Battery Instructions C Download Email Weight Indicators|Indicators / Controllers|Indicator Hardware No
882IS IS6V2 Battery Charger Instructions E Download Email Indicators / Controllers|Weight Indicators|Indicator Hardware No
882IS Fiber Optics to RS-422 Converter B Download Email Indicator Hardware|Indicators / Controllers|Weight Indicators No
882IS Fiber Optics to RS-232 Converter B Download Email Weight Indicators|Indicators / Controllers|Indicator Hardware No
882IS/882IS Plus Conditions of Use C Download Email Intrinsically Safe|Indicators / Controllers|Weight Indicators No
882IS mb-EPS-100-240-X2 Power Supply Instructions A Download Email Indicator Hardware|Indicators / Controllers|Weight Indicators No
882IS I/O Module Installation A Download Email Indicators / Controllers|Weight Indicators|Indicator Hardware No
882IS Intrinsically Safe Indicator Battery Tester Instruction Addendum A Download Email Indicators / Controllers|Indicator Hardware/Options No
882IS IS6V2 Battery and Barrier Connector Assembly Replacement A Download Email Indicator Hardware/Options No
920i Setpoint Configuration with 882IS/882IS Plus A Download Email Indicator Software|Indicators / Controllers|Weight Indicators No
882IS IS6V2 Battery Charger Instructions (Archived) D Download Email Indicators / Controllers|Weight Indicators|Indicator Hardware Yes

Title Download Email
Hazardous Area Classification Download Email

Title Download Email
882IS/882IS Plus Replacement Parts Catalog Page Download Email

Title Collateral Wizard Request Download Email Category
882IS/882IS Plus Intrinsically Safe Indicator Request Download Email Indicators / Controllers

Title Version Size Release Date Download Email
882IS Firmware 1.09.01 159.9 KB 05/06/2022 Download Email
882IS IO Module Firmware 1.03.01 178.7 KB 12/07/2023 Download Email
920i iRite with 882IS Setpoints Application 1.01 5.4 KB 02/25/2021 Download Email

Title Version Size Release Date Download Email
Revolution Scale Software (v3.46) 3.46 236.3 MB 02/15/2024 Download Email

Title View Download Email Category
ScaleTalk: What are Hazardous Areas? View Download Email
ScaleTalk: Three Types of Protection for Hazardous Locations View Download Email Intrinsically Safe
882IS: Calibrating a Scale (Interactive) View Email Weight Indicators|Indicators / Controllers|Intrinsically Safe
882IS: Configuring Capacity (Interactive) View Email Weight Indicators|Indicators / Controllers|Intrinsically Safe
882IS: Defaulting the Indicator (Interactive) View Email Weight Indicators|Indicators / Controllers|Intrinsically Safe
882IS: Enabling Streaming (Interactive) View Email Weight Indicators|Indicators / Controllers|Intrinsically Safe

Title Download Email
882IS Control Drawing Download Email
IS6V2 Battery Control Drawing Download Email
mb-EPS-100-240-X2 Power Supply Control Drawing Download Email

Parts

882IS

Part # Description List Price Cart
195091 Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Standard Tilt Stand

List Price: $1,525.00

185288 Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC charger NEMA 5-15(North American plug)

List Price: $2,455.00

194231 Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC CEE 7/7 Continental Europe Charger

List Price: $2,455.00

196273 Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC AU Charger

List Price: $2,455.00

185290 Indicator,882IS 7.5 VDC SST Encl. 5 Button Keypad W/AC Power Supply w/10ft(3m) PS cable 115-230VAC

List Price: $2,685.00

194235 Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With A/C Power Supply. 115-230VAC with metric thread adapter (1/2NPT - M20)

List Price: $2,685.00

882IS Plus

Option Cards

Options

Options/Accessories

Part # Description List Price Cart
180831 Battery Option,IS6V2 Barrier Protected, Rechargeable includes M12 22 inch cable

List Price: $685.00

194191 Battery Charger,IS6V2 100-240VAC NEMA 5-15 North America Plug

List Price: $275.00

194189 Battery Charger, IS6V2 100-240VAC CEE 7/7 Continental Europe Plug

List Price: $275.00

194192 Battery Charger, IS6V2 100-240Vac BS1363 UK Molded Plug

List Price: $275.00

197591 Battery Charger, IS6V2 100-240VAC AS/NZS 3112 Australia Plug

List Price: $275.00

180837 Power Supply,882IS mb-EPS-100-240-X2, Dual Output 6.8VDC 200mA

List Price: $1,055.00

195109 Power Supply,882IS Metric MB-EPS-100-240-X2, Dual Output 6.8VDC 200mA Metric thread adapter included 1/2in NPT - M20

List Price: $1,095.00

179668 Cable Assy, Power, 22in, Angle Female, 4 Pins, D-Coded, Hazardous Location

List Price: $76.00

179669 Cable Assy, Power, 10ft, Shielded, 20 AWG / 4 Conductors, M12 Straight Male to M12 Right Angle Female, 4 Pins, D-Coded, Hazardous Location

List Price: $149.00

179670 Cable Assy, Power, 50ft, Shielded, 20 AWG / 4 Conductors, M12 Straight Male to M12 Right Angle Female, 4 Pins, D-Coded, Hazardous Location

List Price: $185.00

179671 Cable Assy, Power, 100ft, Shielded, 20 AWG / 4 Conductors, M12 Straight Male to M12 Right Angle Female, 4 Pins, D-Coded, Hazardous Location

List Price: $360.00

190979 Lockout Device, M12 Cable 882 Battery Box Lockout Device

List Price: $24.00

163751 Tilt Stand,880 Desktop

List Price: $41.00

179678 Tilt Stand,882IS Battery IS6V2 Option

List Price: $45.00

177850 Panel,Mount Option 880, 882D, 882IS Universal Indicator, Gasketed Non-NEMA Seal.

List Price: $215.00

206735 Battery Tester,882IS

List Price: $375.00

I/O Module

Option Cards

Remote Indicator for Setpoint Functionality

Replacement Parts

Replacement parts can only be purchased through trained and authorized dealers. You must be logged in as a dealer to view any available replacement parts.

To locate a dealer in your area, please call us at 1-800-472-6703 or fill out a request online.

Website Experience

For optimal performance, please use a current version of Google Chrome or Microsoft Edge. Rice Lake and our third-party partners collect data and use cookies in order to personalize advertising and analyze traffic. Read our privacy policy for more information

Agree and Continue Close