882IS/882IS Plus Intrinsically Safe Digital Weight Indicator

Standard Features
- LCD display with white LED backlight
- T4 temperature rating
- Battery life display icon
- Numeric keypad (882IS Plus)
- Dual duplex fiber-optic interface
- Power ON/OFF; battery save mode
- Configurable local/remote mode
- I/O module option: one serial port, optional analog output, optional fieldbus cards, Ethernet TCP/IP
- Time and date (requires I/O module)
- Setpoint functionality using secondary 920i® indicator
- FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file number 221416
Intrinsically Safe Scale Indicator for Hazardous Locations
The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications. The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements.
Enhanced Connectivity
Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module. To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator.
882IS/882IS Plus Intrinsically Safe Digital Weight Indicator Specifications
Power: Power Consumption: Battery (optional): Load Cell Excitation: Load Cell Current: Load Cell Cabling: Analog Signal Input Range: Analog Signal Sensitivity: Resolution: |
Conversion Rate: Annunciators: Motion Band: Display Increments: Display: Keys/Buttons: Temperature: |
Rating/Material: Weight: Warranty: Intrinsic Safety: Approvals: |
882IS/882IS Plus Intrinsically Safe Digital Weight Indicator Dimensions
Dimensions | |||
---|---|---|---|
Without Battery | |||
A | 8.94 in (227 mm) | E | 9.96 in (253 mm) |
B | 7.66 in (195 mm) | F | 4.36 in (111 mm) |
C | 6.50 in (165 mm) | G | 8.37 in (213 mm) |
D | 8.10 in (206 mm) | ||
With Optional Battery and Tilt Stand | |||
H | 4.64 in (118 mm) | K | 10.29 in (261 mm) |
I | 5.00 in (127 mm) | L | 13.06 in (332 mm) |
J | 9.03 in (229 mm) |
Dimensions | |||
---|---|---|---|
Optional Power Supply | |||
A | 9.25 in (235 mm) | C | 3.11 in (79 mm) |
B | 6.20 in (158 mm) |
Dimensions | |||
---|---|---|---|
Optional I/O Module | |||
A | 10.00 in (254 mm) | C | 6.91 in (176 mm) |
B | 9.13 in (232 mm) | D | 4.00 in (102 mm) |
Control Drawings
Parts
Part # | Description |
---|---|
882IS | |
195091 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Standard Tilt Stand The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
185288 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC charger NEMA 5-15(North American plug) The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code(Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C DB Ta = -10C to 40C(14F to 104F) and ATEX/IECEx 1G Ex ia IIC T4 Ga II 2D Ex ib IIIC T135C Db. It is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and end users hazardous (classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
194231 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC CEE 7/7 Continental Europe Charger The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
196273 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC AU Charger The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
185290 | Indicator,882IS 7.5 VDC SST Encl. 5 Button Keypad W/AC Power Supply w/10ft(3m) PS cable 115-230VAC The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as : Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class 1, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II sD Ex ib IIIC T135C Db. It is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and users hazardous (classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations is the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
194235 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With A/C Power Supply. 115-230VAC with metric thread adapter (1/2NPT - M20) The 882IS is designed and approved for use in specific Hazardous (classified) areas by by Factory Mutual(FM). These areas are classified by the NFPA, National Electric Code(Article 500) as: Class I,II,II Divisions 1 or 2 GROUPS ABCDEFG T4 and Class 1 Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G ia IIC T4 Ga II 2D Ex ib IIIC T135C Db. It is the responsibility of the reseller to keep a permanent traceable record of the location(end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed byu the reseller and the end users Hazardous (classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service are the responsibility of the end user. Any field modification of tghe product voids any and all warranty and FM Approval. |
194232 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC BS 1363 UK Charger The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
882IS Plus | |
195092 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Standard Tilt Stand The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code(Article 500) as: Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2D Ex ib IIIC T135C Db. It is the responsibility of the reseller to keep a permanent traceable record of the location(end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and the end users hazardous (classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
185291 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand 115-230VAC charger NEMA 5-15(North American plug) The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
194233 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand. 115-230VAC CEE 7/7 Continental Europe Charger The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
196274 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand. 115-230VAC AU Charger The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
185293 | Indicator,882IS Plus 7.5 VDC SST Encl. 21 Keypad w/AC Power Supply w/10ft(3m) PS Cable 115-230VAC The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code(Article 500) as: Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2D Ex ib IIIC T135C Db. It is the responsibility of the reseller to keep a permanent traceable record of the location(end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and the end users hazardous (classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
194236 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With A/C Power Supply. 115-230VAC with metric thread adapter (1/2 NPT - M20) The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
194234 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand. 115-230VAC BS 1363 UK Charger The 882IS is designed and approved for use in specific Hazardous (classified) areas by Factory Mutual(FM). These areas are classified by the NFPA70, National Electric Code (Article 500) as :Class I,II,III Divisions 1 or 2 and Groups ABCDEFG T4 and Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135C Db Ta = -10C to 40C(14F to 104F) and ATEX/IECEx II 1G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135C Db it is the responsibility of the reseller to keep a permanent traceable record of the location (end user) of the Equipment or return a completed Rice Lake Weighing Systems "Hazardous Area Classification Form" signed by the reseller and and users hazardous(classified) area defining authority for our acceptance and permanent record. Proper specification, installation, operation and service of this equipment to National and Local regulations are the responsibility of the end user. Any field modifications of the product voids any and all warranty and FM Approval. |
Options
Part # | Description |
---|---|
Options/Accessories | |
180831 | Battery Option,IS6V2 Barrier Protected, Rechargeable includes M12 22 inch cable |
194191 | Battery Charger,IS6V2 100-240VAC NEMA 5-15 North America Plug |
194189 | Battery Charger, IS6V2 100-240VAC CEE 7/7 Continental Europe Plug |
194192 | Battery Charger, IS6V2 100-240Vac BS1363 UK Molded Plug |
197591 | Battery Charger, IS6V2 100-240VAC AS/NZS 3112 Australia Plug |
180837 | Power Supply,882IS mb-EPS-100-240-X2, Dual Output 6.8VDC 200mA |
195109 | Power Supply,882IS Metric MB-EPS-100-240-X2, Dual Output 6.8VDC 200mA Metric thread adapter included 1/2in NPT - M20 |
179668 | Cable Assy, Power, 22in, Angle Female, 4 Pins, D-Coded, Hazardous Location |
179669 | Cable Assy, Power, 10ft, Shielded, 20 AWG / 4 Conductors, M12 Straight Male to M12 Right Angle Female, 4 Pins, D-Coded, Hazardous Location |
179670 | Cable Assy, Power, 50ft, Shielded, 20 AWG / 4 Conductors, M12 Straight Male to M12 Right Angle Female, 4 Pins, D-Coded, Hazardous Location |
179671 | Cable Assy, Power, 100ft, Shielded, 20 AWG / 4 Conductors, M12 Straight Male to M12 Right Angle Female, 4 Pins, D-Coded, Hazardous Location |
190979 | Lockout Device, M12 Cable 882 Battery Box Lockout Device |
163751 | Tilt Stand,880 Desktop |
179678 | Tilt Stand,882IS Battery IS6V2 Option |
177850 | Panel,Mount Option 880, 882D, 882IS Universal Indicator, Gasketed Non-NEMA Seal. |
206735 | Battery Tester,882IS |
I/O Module | |
177709 | Module,882 Smart I/O Interface for 882IS Smart Card Interface, Ethernet Fiber-Optic interface |
196166 | Module,882 Smart I/O Interface for 882IS Smart Card Interface, (EU power cord) Ethernet, Fiber-Optic interface |
196769 | Option,Fiber/RS232 6x6 FRP Enclosure, Fiber Optic-232 converter, Ext. Power Supply |
196770 | Option,Fiber/RS422 6x6 FRP Enclosure, Fiber-RS422 converter, External Power Supply |
78026 | Cable,Plastic Optical 100 ft. includes polishing kit |
78027 | Cable,Plastic Optical 200 ft. includes polishing kit |
197384 | Kit,Polishing POF Cable Includes: 1 - 197381 Polishing Films 1 - 197383 Polishing Puck |
Network and Fieldbus Interface Cards | |
190528 | 882 Opt,Single Analog Output (0-10VDC, 0-20mA, 4-20mA) |
190530 | 882 Opt,Ethernet/IP CompactCom Option |
190531 | 882 Opt,DeviceNet CompactCom Option |
190532 | 882 Opt,ProfiNet CompactCom Option |
190534 | 882 Opt,Profibus CompactCom Option |
190533 | 882 Opt,Modbus TCP CompactCom Option |
190535 | 882 Opt,EtherCAT CompactCom Option |
Remote Indicator for Setpoint Functionality | |
203343 | Indicator,920i Universal ASSY 115 VAC, No A/D Board, includes 201804 882IS interface iRite software. |
203344 | Indicator,920i Wall Mount Assy, 115 VAC, No A/D Board, includes 201804 882IS interface iRite software. Requires fiber convertor PN(196769 or 196770) |
An ISO 9001 Registered Company ©2024 Rice Lake Weighing Systems